EFILive Release Notes

June 02, 2015

Version Numbers

     V7.5 Software: V7.5.7, Build 285

     V8 Software: V8.2.2, Build 278

     FlashScan/AutoCal Firmware: V2.07.84 (Jun 02, 2015)

     FlashScan/AutoCal Boot Block: V2.07.07 (Feb 07, 2014)

EFILive V7.5

Enhancements:

     Added a warning when saving a tune file with Auto-Lock active but without the “Cannot be Viewed or Modified” security restriction.

     Controllers that have a key of $0000 can now be “unlocked” using the Unlock window.

Bug Fixes:

     None.

EFILive V8

Known Issues:

     When Black Box Logging PIDs from an ECM and TCM simultaneously and a PID is selected from the transmission controller (TCM) that has an identically named PID in the engine controller (ECM), (i.e. RPM) then when the log file is opened in the V8 software for viewing, the TCM PID will be displayed as if it originated from the ECM. The PID's data will have correctly been logged from the TCM, only its name will appear to indicate that it was logged from the ECM.
Workaround: None. It is a restriction of the *.efi (V7.5 log file format). That restriction will be removed and the TCM PIDs will display their true origin once the V8 scan tool software is available.

Enhancements:

     Added a warning when saving a tune file with Auto-Lock active but without the “Cannot be Viewed or Modified” security restriction.

     The [F4: OBD] tab page is now operational. Features include System Readiness Test results and DTC display.

     Added option to double click (or drag) a *.bbx file to start EFILive with that *.bbx quick setup file pre-loaded.

     Quick setup (*.bbx) files can now be double-clicked, or dragged onto the V8 software to automatically open the quick setup file in the [F5: BBX] -> [F6: Quick Setup] tab page.

     Quick setup (*.bbx) files now have a unique icon in Windows Explorer.

     Calibration only (*.coz) files now have a unique icon in Windows Explorer.

Bug Fixes:

     LML recovery after a failed flash may fail with $0333 “Security Access Denied” error.

     LS1B and LB7 full flash may set the seed/key combination to $0000/$0000 causing the EFILive software to presume the controller is locked. Subsequent read and/or flash attempts fail with $0333 “Security Access Denied” error.

     Various scan tool improvements for computing calculated PIDs, filtering and searching log files.

     The GM.EOPS PID was not being imported correctly from V7 *.efi log files.

FlashScan/AutoCal

Enhancements:

     Power-up key options have changed, see table below.

 

FlashScan

AutoCal

Dead-Poll

Ctrl

Ok

Advanced Menu

-

Next

Factory Defaults

F1

Prev

Factory Defaults and Format Config File System

F1+F3

Prev+Next

 

Bug Fixes:

     None.

 

Documentation Updates

·         EFILocker COS Patch.pdf

·         Cummins 2010-15 Quick Start.pdf

·         Cummins 2006-09 Quick Start.pdf

·         EFILive AutoCal Info for End Users Guide.pdf.

Knowledgebase Updates

·         Power Up Options: https://support.efilive.com/kb_article.php?ref=9131-UZCN-1168